ET-24

FEATURES&APPLICATIONS
• Used in low to medium power AC-DC power supplies
• Designed for line to neutral safety clearance
• High impedance at applicable frequency
• High self-resonant frequency
• Dielectric withstanding voltage rated at 2500 VAC line to line
• Signal line filtering

 

According to:                                                                   

 

 

 

ET-24

PART NUMBER

    TERMINAL PINS

Dimension in mm

A

B

C±0.5

D±0.5

E±0.5

F±0.5

FIG

ET-24-01-H

  4

 26

  26

15

4

12

26

NO.1

ET-24-02-V

  4

31

19

10

4

13

26

NO.2

PART NUMBER

   Inductance

(mH MIN)

Irms

(  A Max)

     DCR

(Ohms ±20%)

ET-24-1.0

  1.0

  2.10

   0.067

  ET-24-1.2

  1.2

  2.00

   0.082

ET-24-1.5

  1.5

  1.60

   0.119

ET-24-2.2

  2.2

  1.50

   0.153

ET-24-2.7

  2.7

  1.30

   0.197

ET-24-3.9

  3.9

  1.00

   0.294

ET-24-4.7

  4.7

  1.00

   0.294

ET-24-6.8

 6.8

  0.80

   0.519

ET-24-8.2

  8.2

  0.70

   0.574

  ET-24-18.0

  18.0

  0.50

   1.271

ET-24-22.0

  22.0

  0.40

   1.564

ET-24-33.0

  33.0

  0.40

   1.790

ET-24-47.0

  47.0

  0.30

   2.768

ET-24-68.0

  68.0

      0.25

   4.024

NOTES:
1. ELECTRICAL SPECIFICATIONS MEASURED AT 25ºC
2. Irms - CURRENT THAT CAUSES THE TEMPERATURE TO
RISE APPROX. 40ºC ABOVE AMBIENT OF 25ºC
3. INDUCTANCE TESTED AT 10 kHz, 0.1 Vrms