Pin-typee anti-DC Current transformer

※ Meet the standard of IEC62053 and ANSI12.20
※ High linearity with DC immunity characteristics
※ Steady phase shift
※ Perfect insulation and excellent immunity of humidity ans shock
※ Various choices for different configurations
※ Meet ROHS requirements
   Application
※ Electronic energy meter ,Power meter
※ Accurate measuring meter for AC at the existing DC components

According to:                                                             

 

 

 

Pin-typee anti-DC Current transformer

P/N

A
(min)

B
(max)

C
(max)

D
(max)

E
(±0.2)

F
(±0.3)

G
(±0.2)

H
(±0.2)

PCT701

7.00 

23.40 

11.00 

24.60 

15.00 

5.00 

19.00 

10.00 

PCT702

8.70 

26.40 

17.00 

28.40 

15.00 

5.00 

19.00 

16.00 

PCT703

12.80 

37.20 

14.00 

38.60 

25.00 

5.00 

32.50 

13.00 

PCT704

8.00 

24.20 

11.80 

25.40 

15.20 

4.60 

 

 

PCT901

18.50 

50.00 

20.00 

55.00 

29.40 

5.00 

37.40 

19.00 

P/N

Rated current 

Rated load resistance

Ratio current 

5A Linearity error 

20A linearity error 

Max current linearity error 

Accuracy class

PCT701

5~60A

10Ω

2500:1

-0.15%

-0.08%

0.05%

0.2%

PCT702

5~80A

10Ω

2500:1

-0.09%

-0.05%

-0.01%

0.1%

PCT703

5~100A

10Ω

2500:1

-0.06%

-0.02%

0.00%

0.1%

PCT704

5~60A

10Ω

2000:1

-0.16%

-0.07%

0.06%

0.2%

PCT901

10~150A

10Ω

2500:1

-0.06%

-0.01%

0.01%

0.1%

Other specifications can be supplied according to your requirement