Coil Components GFCI

※ Accord with UL943 standard

※ Accurate output characteristic, avoid complex procedures of resistance

※ Excellent overload current characteristic, resist heavy current shock effectively 

※ Range of work temperature: -35℃~80℃

※ Accord with RoHS require

Application

GFCI(Ground Fault Circuit Interrupters)

According to:                                                                       

 

 

 

Coil Components GFCI

Model

A
(min)

B
(max)

C
(max)

D
(max)

E
(±0.2)

F
(±0.3)

G
(±0.2)

H
(±0.2)

Z/G522

6.00

23.20

11.00

21.80

20.00

4.00

8.00

 

Z/G523

4.00

16.00

11.50

5.00

11.00

4.00

1.50

 

Z/G524

3.70

17.20

11.00

14.00

18.60

4.00

3.60

 

Z/G530

19.80

38.00

16.50

42.60

2.50

9.80

13.00

 

Z/G961

5.60

16.60

11.00

16.60

15.00

4.00

6.50

 

 

Model 

Rated current 
(A)

Differential coil

Neutral coil 

output characteristic

 temperature characteristic

balance characteristic

inductance

 temperature characteristic

5mA/1KΩ

-35℃~80℃

20A/1KΩ

1KHz/1V

-35℃~80℃

Z/G522

20

3.3~4.0mV

10%max

0.4mVmax

80mH REF

25%max

Z/G523

20

3.3~4.0mV

10%max

0.4mVmax

80mH REF

25%max

Z/G524

20

3.3~4.0mV

10%max

0.4mVmax

80mH REF

25%max

Z/G961

20

3.3~4.0mV

10%max

0.4mVmax

80mH REF

25%max

Z/G530

40

3.6~4.6mV

10%max

0.4mVmax

80mH REF

25%max

Note: The above is the natural specification, some technical parameters could be updated according to your requirement.